CE-marked
The product has performed the requirements for electromagnetic compatibility in accordance with EEC Directive 98/34, European Standard EN61000-6-1
The module inductively reads the number of rotations on the metal indicator located under the glass on the water meter's display board. The relation between the number rotations and the read pointer is equal to D. D=number of liters per pulse and found in different pulse numbers, e.g 1, 10 and 100.
The AT 7275RES has a built-in lithium battery for more than 10 years of operation. Measurement value and settings are maintained in case of power failure (e.g M-bus loop failure). In case of power failure, the data bus (M-bus and Mini-bus) will continue to register the values.
Ordering number | |
---|---|
- M-bus module (Residia-M), can be parameterized as desired, For example, primary dressing is indicated when ordering | |
- M-bus module, mounted on the meter and parametric | AT 7080A-15VVM, 7080A-15KVM, |
AT 7085A-15VVM, 7085A-15KVM | |
- Radio module (Aramatec radio) | AT 7275ARES-R |
M-bus/Mini-bus module, Residia-M, AT 7275RES-M | |
M-bus interface | Automatic speed recognition (300/2400 Baud) |
Protocol | acc. EN13757-3 equiv. IEC 870/EN1434-3 |
Data | Manufacturing number, date/time stamp, manufacturer, Media, Model/Version, |
Accumulated volume (1 liters resolution). Volume flow | |
Accumulated negative volume, measurement site-ID, logged values | |
Adressing | Primary address (=000 By default, can be programmed before or after delivery) |
Secondary address (sensor manufacturer's number) | |
M-Buslast | 1 unit load (1,5 mA) |
Cable length | 1,5 m can be extended in accordance with the M-Bus standard. |
Battery | 3 V Lithium, > 10 year's Life span |
With unbroken cable, life expectancy increases > 15 år. | |
In case of cable failure, the battery supplies the storage function and meter registration. | |
Ambient temperature | |
- For transport and storage | -20...+65º C |
- In operation | -10...+65º C |
Protection | IP 65 (mounted), IP 54 (unassembled) |
Weight | 30 g |
Pulse module, Residia-P, AT 7275RES-PD.. | ||
Type | Open collector ISO/TC30 (polarity)* | |
Vmax / Imax / Pmax / fmax | 30V / 20mA / 0,48VA / 5 Hz | |
Max volt vid stängt relä | 0,7V+I*47Ω | |
Pulse length | 124 ms | |
Cable length | 1,5 m | |
Battery | 3 V Lithium, > 10 year's life span | |
Ambient temperature | ||
- For transport and storage | -20...+65º C | |
- In operation | -10...+65º C | |
Protection | IP 65 (mounted), IP 54 (unassembled) | |
Weight | 30 g | |
*To get a potential-free pulse, the AT 7281-2PCD must be mounted after the pulse sensor. |
Armatec radiomodul, AT 7275ARES-R | |
---|---|
Power supply | 3,6 V/1,6 Ah, lihtium-battery |
Battery life span | 5 år |
Radio frequency | 868 to 868,6 MHz |
Transmission power | 5mW |
Ambient temperature | |
- For transport and storage | -20 to 50°C |
- In operation | -20 to 50°C |
Protection | IP 32 |
Weight |
Wireless M-Bus module, AT 7275RES-WM | |
Power supply | 3,6 V/1,6 Ah lithium-battery |
Battery life span | 5 years |
Radio frequency | 868,7 to 869,2 MHz |
Transmission power | 5mW |
Ambient temperature | |
- For transport and storage | -20 to 50°C |
- In operation | -20 to 50°C |
Protection | IP 32 |
When installing the remote reading modules, the sealed cover is removed and replaced with thye remote reading module. Protective film on the underside of the module must be removed before assembly. The supplied sealing tape is attached over the joint between the meter housing and the remote reading module to detect engagement or manipulation.
Remote reading module:
The primary M-bus address is preset to 000, the secondary address corresponds to the M-bus module manufacturing number. Addressing as well as the meter's starting value can be set according to the M-bus standard, service software MiniCom 3 is available for downloading on Armatec's website.
Signal cables according to:
M-bus module: Green=Data cable, Brown=Earth
Pulse module: White=Pulse (+), Brown=Earth
The remote reading modules are marked as follows:
- Residia-P : Pulse module with pulse value D=1, 10 etc.
- Residia-M : M-bus module
- Residia-R : Radio module
Every remote reading module has an 8-digit manufacturing number. For the M-bus module, this corresponds to the secondary suit.
Ordering number | RSK-number | |
---|---|---|
- M-bus module for apartment meter AT 7080/7085 | AT 7275RES-M | 518 20 49 |
- Pulse module with pulse number 1 pulse/liter | AT 7275RES-PD1 | 518 20 50 |
- Puls module with pulse number 1 pulse/10 liters | AT 7275RES-PD10 | 518 20 50 |
- Puls module for pulse number 1 pulse/100 liters | AT 7275RES-PD100 | |
- Radio moduel for Armatec Radio | AT 7275ARES-R |