Rotary piston volumetric type cold water meter with accuracy R160. For horizontal and vertical mounting. Low starting flow allows leakage detection. Pre-equipped for communication through Cyble module, pulse/data (M-bus)/ sensor, type AT 727CY.
Dimension range | G 3/4 - G 2 |
---|---|
PN | 16 |
Temperature range | Max +50ºC |
Material | Composite/Brass |
Article number | Amount |
---|---|
AT 7430B15-2,5 | |
AT 7430B20-2,5 | |
AT 7420B15-2,5 | |
AT 7420B20-4 | |
AT 7420B25-6,3 | |
AT 7420B25-10 | |
AT 7420B40-16 | |
AT 7275CY-M | |
AT 7275CY-WM | |
AT 7275CY-KLF1 | |
AT 7275CY-KLF10 |
Dimension range | PN | Temperature range | Material |
---|---|---|---|
G 3/4 - G 2 | 16 | +2 °C to +50 ºC | Brass |
G 3/4 - G 1 | 16 | +2 °C to +50 ºC | Composite |
UGE.35 Water meter for flow, pipe mounted with digital display, accumulated worth.
Meter with a rotary piston measuring chamber design for cold water AT 7420B-....., Q3 .... m³/h, DN ...., PN 16, in brass. Prepared for mounting of pulse, M-Bus sensor type Cyble.
Meter with a rotarypiston measuring chamber design for cold water AT 7430B-....., Q3 .... m³/h, DN ....., PN 16, in composite. Prepared for mounting of pulse, M-bus sensor type Cyble.
Component | Material | |
---|---|---|
1 | Body and insert ring | AT 7420B: Brass CW617N AT 7430B: composite PPA |
Q3 2,5 fd Qn 1,5 AT 7420 | Q3 2,5 fd Qn 1,5 AT 7430 | Q3 4 fd Qn 2,5 AT 7420 | Q3 4 fd Qn 2,5 AT 7430 | Q3 6,3 AT 7420B | Q3 10 | Q3 16 AT 7420B | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Connection after coupling | DN15 | DN15 | DN20 | DN20 | DN 20 | DN25 | DN40 | ||||||||||||
A (Length) | 110 | 110 | 190 | 190 | 260 | 260 | 300 | ||||||||||||
B | 115 | 123 | 143 | 123 | 143 | 178 | 180 | ||||||||||||
C | 22 | 26 | 20 | 26 | 42 | 55 | 57 | ||||||||||||
D | 85 | 92 | 88 | 92 | 104 | 140 | 140 | ||||||||||||
Connection, meter | G 3/4" | G 3/4" | G 1" | G 1" | G 11/4" | G 11/4" | G 2" | ||||||||||||
Weight | 0,95 | 0,6 | 1,5 | 0,68 | 2,6 | 5,4 | 6,2 | ||||||||||||
Dimensions in mm, weight in kg |
AT 7420B is a water meter with a rotary piston measuring chamber design for cold water with an accuracy of R160. This means that the meter measures extremely thoroughly even at low flows. The design of the rotary piston meter allows mounting of the meter in any position with the exception of the meter body facing downwards. Piston meter AT 7420B doesn't have any after rotation. The meter has a self cleaning function and never goes against plus during its expiration time.
Piston meter AT 7420B is provided with indication display for connection of remote reading modules type Cyble, with M-Bus, wM-Bus and pulse. See separate product sheet AT 7275CY.
Cyble is an inductive AMR-system (Automatic Reading System) for remote reading and transfer of readings from the water meter to the measurement collection system. TheCyble-sensor's rotational frequency is read inductively through a metal fitted dial indicator.
Cyble-sensor can be mounted directly or at a later point, the meter's glass is prepared with attachment points with the help of the accompanying screws.
AT 7430B is made in composite. This means that the meter's manufacturing process is environmentally friendly through, among other things, less energy consumption and lack of heavy metalls like lead, zinc and copper. The material in the meter is 100% recyclable and has a high resistance against chlorine and other substances that can be found in drinking water. Composite has the same strength as brass but with a significantly higher elasticity, which make meter bodies in composite absorbing pressure stroke better without taking damage. The material's low weight also makes it easier to store, handle and transport.
Meteorological properties | AT 7420B15-2,5 | AT 7420B20-4 | ||||
---|---|---|---|---|---|---|
AT 7430B15-2,5/7430B20-2,5 | ||||||
Q3 | Permanent flow, m3/h (meter size) | 2,5 | 4 | |||
R | Ratio (Q3/Q1) (Standard is R160) | 160 | 160 | |||
Start flow, l/h. The value is for R400. | <1 | <2 | ||||
Q1 | Minimum flow, l/h (tolerance +- 5%). The value is for R160. | 15,6 | 25 | |||
Q2 | Boundary flow, l/h (tolerance +-2%). The value is for R160. | 25 | 40 | |||
Q4 | Overload flow, m3/h | 3,1 | 5,0 | |||
The values in the table above are within the meteorological properties that are described in Swedac's regulations for MID 2004/22/EC and EN 14154 (The machine instrument directive) |
Meteorological properties | 7420B25-6,3 | 7420B25-10 | 7420B40-16 | ||||
---|---|---|---|---|---|---|---|
Q3 | Permanent flow, m3/h (meter size) | 6,3 | 10 | 16 | |||
R | Ratio (Q3/Q1) (Standard is R160) | 160 | 160 | 160 | |||
Q1 | Minimum flow, l/h (tolerance +- 5%) | 39 | 63 | 100 | |||
Q2 | Transitional flow, l/h (tolerance +-2%) | 63 | 100 | 160 | |||
Q4 | Overload flow, m3/h | 7,9 | 12,5 | 20 | |||
The values in the table above describes the meteorological properties in Swedac's regulations for MID 2004/22/EC and EN 14154 (Machine Instrument Directive). The gauges characteristic is well within these values. |
Flow range | Q1 - Q2 (Qmin - Qt) | ± 5% |
Q2 - Q4 (Qn - Qmax) | ± 2% |
- Meter body in composite material - AT 7430B.
- Installation accessories, consoles and parallel couplings, se separate product sheet for AT 7358, 7539, 75360.
Remote reading module type Cyble
The meter is provided with an indicator that registers meter readings, flow direction in a remote reading module type Cyble, that can be mounted on the meter glass. The Cyble-module can be ordered with pulse 1/10/100 liter per pulse, wM-Bus or M-Bus.
For more technical information see more in separate product sheet AT 7275CY.
Remote reading module type HRI with pulse output. Pulse type transistor (open collector), polarity dependent | Pulse values (l/puls)* | |
---|---|---|
AT 7275HRI-A4-D1 | 1 | |
AT 7275HRI-A4-D10 (most common, "standard") | 10 | |
AT 7275HRI-A4-D100 | 100 | |
* When there is need for other pulse values above standard see product sheet for AT 7275HRI. |
Remote reading module type HRI med data output for M-Bus and Mini-Bus | Pulse values by delivery* (l/puls) | |
---|---|---|
AT 7275HRI-B4-D1 | 1 | |
* Pulse values can be reprogrammed through service software MiniCom |
Water meter size | Cartridge check valve including gasket |
---|---|
DN 20 | AT 7059A20 |
DN 25 | AT 7059M25 |
DN 40 | AT 7059M40 |
Dimension DN | Meter size | Article number | RSK-number |
---|---|---|---|
15 | Q3 2,5 | AT 7420B15-2,5 | 5143842 |
15 | Q3 2,5 | AT 7430B15-2,5 (composite) | 5143847 |
20 | Q3 4 | AT 7420A20-4 | 5143843 |
20 | Q3 4 | AT 7430B20-2,5 (composite) | 5143848 |
25 | Q3 6,3 | AT 7420B25-6,3 | 5143844 |
25 | Q3 10 | AT 7420B25-10 | 5143845 |
40 | Q3 16 | AT 7420B40-16 | 5143846 |