Main facts
Dimension range | PN | Temperature range | Material |
---|
G 1/2 | 20 | 5°C to +80ºC | Stainless steel |
Range of application
Immediate measurement of the flow of air or water.
AMA-text
UGE.31 Flow gauge
Tube mounted with analog current flow indication.
Quality assurance
According to PED 2016:1
Material specification
| | |
---|
1 | Body | Stainless steel 1.4401 |
2 | Flow tube | Grilamid (PA-12) |
3 | Float | Stainless steel 1.4460 ór1.4460/PTFE depending on the measure area |
4 | End piece | Nylon |
Dimension and weight
| |
---|
A | 53 |
B | 202 |
C | 34 |
D | 134 |
E | 38 |
Weight | ca 950g |
Function and design
Float gauge in fluidised body-type for air or water. Measurement range in water 0.4 l / min to 30l / min and range in air 15Nl / min to 700Nl / min.
The instantaneous flow is read by the meter visually. The scale is adapted to the media. The flowmeter has an adjustment screw and is prepared for flow alarm.
Technical information
| |
---|
Adjustability | Adjusting screw |
ambient temperature | 0°C to +65°C |
Media temperature | 5°C to +85°C |
Storage temperature | 5°C to +65°C |
Inaccuracy | ±5% |
Accessories and options
Flowmeters in other materials or for higher temperature on request.
Installation
The flowmeter is installed in the flow direction horizontally.
Marking
The pressure sensor is labeled with the manufacturer's name, measuring range and serial number.
How to order
AT7730-3V | | |
AT 7730 | 3 | V |
---|
Fig. no | Flow area (l/min) | V=Water |
| | L=Air |
Pressure range
AT 4883 | -1 | -2,5 | -6 | -10 | -16 | -25 | -40 | -60 | -100 |
---|
Pressure range bar | 0-1 | 0-2,5 | 0-6 | 0-10 | 0-16 | 0-25 | 0-40 | 0-60 | 0-100 |
Max. pressure bar | 10 | 16 | 30 | 30 | 50 | 50 | 70 | 70 | 200 |