Electric actuator for on/off or control of ball valves, butterfly or where a 90° rotation is required.
Torque | 100 Nm to 800 Nm |
---|---|
Power supply | Electric 230V, 3x400V or 24VDC |
Valves | AT3502, AT3507, AT3533S, AT3534S, AT3542, AT3547, AT3582, AT3585, AT3590, AT2282, AT 2310-2319, AT2270B |
Article number | Amount |
---|---|
AT 3941-10 | |
AT 3941-10-POS | |
AT 3941-10-24VDC | |
AT 3941-10-POS24VDC | |
AT 3941-10-400V | |
AT 3941-10-POS400V | |
AT 3941-15 | |
AT 3941-15-POS | |
AT 3941-15-24VDC | |
AT 3941-15-POS24VDC | |
AT 3941-15-400V | |
AT 3941-15-POS400V | |
AT 3941-25 | |
AT 3941-25-POS | |
AT 3941-25-24VDC | |
AT 3941-25-POS24VDC | |
AT 3941-25-400V | |
AT 3941-25-POS400V | |
AT 3941-50 | |
AT 3941-50-POS | |
AT 3941-50-400V | |
AT 3941-50-POS400V | |
AT 3941-80 | |
AT 3941-80-POS | |
AT 3941-80-400V | |
AT 3941-80-POS400V |
UEC.11 actuator for valve, electric, two-position, without spring return
Actuator Bernard Electrical AT 3900 for 90°. Maneuvering of ball-, butterfly- and plug valves.
CE-Marking
EC Directives 2004/108/EC, 2006 /95 /EC and fulfills the EN 61000-6-4, EN 61000-6-2, EN 60034-1 and EN 60529.
IP 67 rated.
Detail | Material | Surface treatment | |
---|---|---|---|
1 | Body | Aluminium | Epoxy painted RAL 2010 |
2 | Cover | Aluminium | Epoxy painted RAL 2010 |
3 | Drive shaft | Steel | Untreated |
Actuator / Fig nr | Standard drive socket | A | B | C | Weight | |||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
3941-10 | 185 | 225 | 290 | 10 | ||||||||||||||||||
3941-15 | 185 | 225 | 290 | 10 | ||||||||||||||||||
3941-25 | 225 | 315 | 320 | 13 | ||||||||||||||||||
3941-50 | 260 | 350 | 330 | 15 | ||||||||||||||||||
3941-80 | 260 | 350 | 330 | 15 | ||||||||||||||||||
Measurements in mm, weight in kg. *Possible to get in different sizes. |
Standard version
Reversible actuator in four sizes, for 0-90° movement, adjustable through a combination of cams, mechanical end stop and/or torque switch.
The acutator is a compact combination of electric motor with thermal overload protection and self-locking, permanently lubricated worm gear. Standard with manual emergency operation and position indicator.
The actuator mounting-dimensions in relation to the fittings are according to ISO 5211.
Design lifetime 20 000 cycles for On/Off or 300 000 starts for modulating. Tested according to EN 15714-2 class A and B
Standard performance | ||||
Motor duty | S4-30% ED. 12 (on/off), S4-50% ED. 12 (positioning/modulating) | |||
Enclosures | IP68 | |||
Temperature | -20°C to +60°C | |||
Anti condensation heater | Yes | |||
Overload protection | Thermostats | |||
Permanently lubricated gear | Gear | |||
Cable entries | 2 st.M20x1,5 for On/Off, 3 pcs for reglulating | |||
End position switches | 250VAC-5A / 48VDC-2,5A | |||
Torque | Yes. 250Nm and above. | |||
Terminal block | 8 connections | |||
During all work with the actuator the power must be disconnected.
The actuator must be connected as per the wiring diagram.
Each actuator must be powered by individual switch or relay contact, minimum 16A,to prevent cross-feed between the actuators.
At outdoor installation, the actuator should be protected by a roof or cap, alternatively choose an actuator with protection class IP67.
Installation with motor downwards should be avoided.
Turn the valve with the control unit's hand wheel to centre position. See indication on top of device.
Always connect the heater.
Check that the actuator turns the valve in the desired direction.
The correct limit switch (open or closed) shall break the motor current.
Cable entries must comply at least to the lowest protection class of devices.
See the instructions for start-up , storage and maintenance.
Article number, manufacturer, serial number, voltage and current.
Wiring diagram is placed by the motor at delivery.
Example | |
AT3941 | 10, 15, 25, 30, 50 och 80 |
---|---|
Fig. no. | Size |
Exemple: 3941-5 (On/Off, 50 Nm, 230V) | |
* 10, 15, 25 eller 50 depending on torque 100, 150, 250, 500 eller 800 Nm | |
* * Option (POS= Positioner 4-20mA eller 0-10V, or for fieldbus contact Armatec) |